SS7 MTP link description
It is consistent with foregoing “Trunk No” of SS7 trunk.
Equipment maximum support 2 signaling links, these two links share workload, when
one link fails, the other link will take over the load until restore from failure, and then
they will share the load again.
If a signaling point has established several signaling links, then the code of each signaling
link will begin from 0.
Indicate which E1/T1 this link is established on, it is stipulated that such numbering is
carried out according to the physical position of E1/T1.
Indicate time slot that link is established on. It is assigned to 1 or 16 for time slot, the
default is 16 time slot.
2.6.3 SS7 Circuit
Figure 2-6-5 SS7 Circuit
Figure 2-6-6 SS7 Circuit description
CIC (circuit identification code) is an important parameter of SS7 circuit. It should be confirmed
with service provider. If the CIC is mismatched, it will result in one-way voice communication.
SS7 Circuit Add
The “Trunk No.” here corresponds to the “Trunk No.” of SS7 trunk.
Fill in the port number of E1/T1. Assign E1/T1 to selected SS7 trunk.
The start of SS7 channel trunk